Wasson色谱石化应用方案之五

一、    850-00  Analysis of boiling point distribution and cut point intervals of crude oils and residues using a single FID.This test method is used to determine the boiling point distribution through a temperature of 720°C. Thistemperature corresponds to the elution of n-C100 per ASTM method D7169.使用单一FID分析沸点分布和削减点间隔的原油和残留。这个试验方法用于确定沸点分布通过温度达到720°C。这是国家ASTM D7169这个温度对应n-C10的淋洗 。  ASTMD7169 
二、    810-00  Detailed Hydrocarbon Analysis of gasoline using an FID. This method applies to gasolineproducts and fractions. DHA analysis also utilizes Dragon Software which can provide: 1)detailed hydrocarbon analysis 2) analysis by hydrocarbon group (PIONA), 3)quantificaiton: weight%, volume%, or mole%, and 4) physical property determination withboiling point distribution: specific gravity, mole wt., RVP. Libraries are available forstraight run gasoline, naphtha, reforming gasoline, FCC gasoline, steam crackinggasoline, isomerization and alkylation, commercial gasoline, oil C-15, and PVT C-20.Analysis can be per ASTM D5134, D6729, or ASTM D6730.使用FID分析详细汽油的碳氢化合物。 这种方法适用于汽油产品和分解。这分析也用龙的软件可以提供:1)详细的碳氢化合物分析2)分析以能组团(PIONA),3)定量:重量%,体积%,或摩尔%,4)物理性质的决心与沸点分布:比重,mole wt。 这些样品是可以直接运行,因为数据库里已有。(汽油、挥发油、重整汽油,FCC汽油、蒸汽裂解汽油、异构化、烷基化、商业汽油、石油C-15,C-20 PVT)。 这分析是根据ASTM D5134, D6729, ASTM D6730  ASTMD5134ASTMD6729ASTMD6730 
三、    135-00  Impurities in Chlorine analysis using dual TCDs and hastelloy hardware for the corrosive environment. Componentsidentified include hydrogen, carbon dioxide, oxygen/argon composite, nitrogen, carbon monoxide, and methane. Lowerdetection limit is 200 ppm per component except carbon monoxide that is 400 ppm.使用双TCDs分析氯气里的杂质和在这腐蚀性环境使用哈氏合金部件。检测的包括:氢、二氧化碳、氧气/氩复合、氮、一氧化碳和甲烷。每个组份的最低的检测限制是200 ppm除了CO是400ppm。
四、    410-00  Trace Impurities in High Purity Gases using a PDHID. Components identified include hydrogen, oxygen/argon composite,nitrogen, methane, carbon monoxide and carbon dioxide in various high purity gas streams. Lower detection limit is50 ppb per component. Argon and oxygen can be separated using cryogenic cooling.使用PDHID在高纯度气体的微量杂质。 分析:氢、氧/氩复合、氮、甲烷、一氧化碳和二氧化碳在各种高纯气体。每个组份的最低的检测限制是50 ppb。 氩和氧气可以使用低温冷却分离。u125-00  Fast Natural Gas analysis with a single TCD for natural gas and natural gas liquids inaccordance with GPA methods 2261 and 2177. 10-peak analysis includes air composite,methane, ethane, propane, isobutane, n-butane, isopentane, n-pentane, nitrogen, carbondioxide and C6+ composite backflush. Lower detection limit is 200 ppm per component.依照GPA2261和2177的方法快速天然气分析与单一TCD对天然气和液态天然气.可分析10个峰包括空气合成物、甲烷、乙烷、丙烷、异丁烷, 2-甲基-2-丁醇,异,正戊烷、氮气、二氧化碳和C6 +以上会被反吹.每个组份的最低的检测限制是200 ppm  GPA 2261GPA 2177 
五、    131-00  Fixed Gases analysis with a single TCD. Components identified include carbon dioxide,ethylene, ethane, acetylene, oxygen/argon composite, nitrogen, methane, hydrogen sulfide,and carbon monoxide. Lower deteciton limit is 200 ppm per component except carbonmonoxide and hydrogen sulfide that are 400 ppm and 500 ppm respectively.固定气体-用一个TCD。 组份确定包括二氧化碳、乙烯、乙烷、乙炔、氧/氩复合、氮、甲烷、硫化氢和一氧化碳。每个组份的最低的检测限制是200 ppm, 除了CO( 400ppm), H2S(500ppm)  Wasson 
六、    135-00  Impurities in Chlorine analysis using dual TCDs and hastelloy hardware for the corrosiveenvironment. Components identified include hydrogen, carbon dioxide, oxygen/argoncomposite, nitrogen, carbon monoxide, and methane. Lower detection limit is 200 ppm percomponent except carbon monoxide that is 400 ppm.使用双TCDs分析氯气里的杂质和在这腐蚀性环境使用哈氏合金部件。检测的包括:氢、二氧化碳、氧气/氩复合、氮、一氧化碳和甲烷。每个组份的最低的检测限制是200 ppm除了CO是400ppm。  Wasson 
七、   159-00  Benzene and Toluene in Motor Fuels with a single TCD. This analysis monitors theconcentrations of benzene (at 0.1% to 5%) and toluene (at 2% to 20%) in motor andaviation gasoline according to the ASTM Method D3606.苯和甲苯在汽车燃油单一TCD。这一分析监控在汽车和航空汽油根据ASTM D3606的方,苯(0.1%到5%)和甲苯(2%到20%)的浓度。  ASTMD3606 
八、   160-00  Flue Gases analysis using dual TCDs. Components identified include helium, hydrogen,carbon dioxide, acetylene, ethylene, ethane, propylene, propane, oxygen/argon composite,nitrogen, methane and carbon monoxide. Lower detection limit is 200 ppm per componentexcept carbon monoxide that is 400 ppm.使用双TCDs烟气分析。分析:氦、氢气、二氧化碳、乙炔、乙烯、乙烯、丙烯、丙烷、氧/氩复合、氮、甲烷和一氧化碳。每个组份的最低的检测限制是200 ppm除了CO是400ppm。  Wasson 

 